• CP-MT-004,MY SHOP,CP-MT-004
  • CP-MT-004,MY SHOP,CP-MT-004

CP-MT-004 Metal-Look Inorganic Fibre Facade Panel

CP-MT-004 metal facade panels in a weathered metal-look finish — an inorganic fibre board for exterior walls and interior feature walls.
  • CP-MT-004,MY SHOP,CP-MT-004

Description

Product Overview

The metal-look band of the CERSAIPANEL range is made for elevations that want the depth of a weathered metal surface without the handling and upkeep of an exposed metal skin. The board behind the face is an inorganic fibre panel formed from coal gasification slag, an industrial by-product that is melted twice at 1,500 °C and restructured into a fully glass-phase material. The finished board is formaldehyde-free and benzene-free, with no toxic volatile organic compounds detected in the supplied test information, and the surface you see is a decorative face carried on that mineral body rather than on metal. Metal facade panels from this band go up on exterior walls and interior walls alike — commercial buildings, institutional projects, hotels and high-end residential work.

It is the panel chosen when a project wants an aged metal look without the weight of stone or the upkeep of real metal cladding. Design teams come to it for the surface, contractors come to it because it handles like a dense mineral board that takes the range's normal fixing details, and distributors come to it because it fills a metal-look slot in a range that also covers stone and wood.

Surface & Colour Control

  • The metal appearance is produced on the panel's decorative face with high-definition 3D printing and electron-beam curing, so the pattern is built into the finished surface rather than applied as a metal foil.
  • This surface reads as warm, weathered metal — a brown, copper-toned pattern with lighter highs and lows rather than a flat, even colour field.
  • Variation from panel to panel is deliberate. A surface that repeats exactly, panel after panel, stops reading as metal and starts reading as print.
  • Approve a physical reference panel before the order is released. The surface is matched to a signed piece, not to a screen image or a printed sheet.
  • Facade metal panels are checked at full panel size, because tone and pattern read very differently across a large panel than they do on a small swatch.
  • On a metal panels facade, light and viewing angle change the tone through the day, so the surface direction is set at design stage and kept consistent across the whole elevation.

Specifications

Property Specification
Base material Inorganic fibre board made from coal gasification slag
Material structure Fully glass-phase, formed by a two-stage 1,500 °C melt
Surface Metal-look decorative face
Panel length Up to 3,050 mm
Panel width Up to 1,220 mm
Thickness 4–15 mm depending on series
Apparent density Approximately 950–1,200 kg/m³ across the range
Screw withdrawal strength At least 1,870 N
Site fabrication Can be cut, drilled, nailed and screwed

Applications & Wall Positions

  • Exterior facade fields on commercial buildings, industrial parks, hotels and residential elevations, where metal facade panels suit the architecture and the elevation is read as one large surface.
  • Entrance zones, canopies and ground-floor elevations, where the panel is seen at close range and the pattern detail does the work.
  • Interior feature walls in lobbies, reception areas, offices and commercial tenant units.
  • Institutional and transport interiors — schools, hospitals, airports, rail stations and museums — where wall surfaces take constant daily use.
  • Ceilings, soffits, partitions, doors, cabinetry and display cabinets.
  • Marine interiors such as ship cabin linings.
  • Refurbishment projects, where a metal panels facade replaces a failing finish without adding the load of a stone or ceramic cladding system.

Material Testing Programme

Test What it covers
Antiviral activity test Surface behaviour of the finished board
Fire resistance test Performance under controlled flame and heat exposure
Mold resistance test Behaviour in humid conditions
Radioactivity test Natural radioactivity of the mineral content
Scrapped-off toy material test Safety of the surface in contact use
VOC test Volatile organic compound emissions

Installation & Fixing

  1. Confirm the fixing method before anything is cut. Exterior work uses wet bonding, riveting or dry hanging, and the approved system design decides which one applies to your wall.
  2. Set out the joint layout and the panel grid on the elevation first — on facade metal panels the grid is what the order is cut to, and changes after cutting are expensive.
  3. Cut, drill, nail and screw the board with ordinary site tools. It machines like a dense mineral board rather than like sheet metal, so there is no special cutting equipment to arrange.
  4. Work from a fixed datum and check plumb and line as you go, especially where a metal panels facade runs across several floors.
  5. Protect the decorative face during handling: keep panels on edge when moving them, and avoid dragging one panel across another.
  6. Keep cut edges clean and free of dust and swarf before trims or sealant go on.
  7. Walk the finished elevation for even tone and consistent joint lines before the scaffolding comes down, and record anything you are not happy with at that stage.

Metal Surface Range

The metal surface band runs from CP-MT-001 to CP-MT-006 — six metal looks in the same board system, differing in tone and pattern rather than in substrate or fixing detail. As exterior metal wall panels suppliers, we hold the whole band, so one project can take two or three metal tones across different elevations and still order a single substrate, a single fixing logic and a single set of details. The same board also comes with stone-look and wood-look faces, and the solid aluminium mosaic line covers interior feature walls where a smaller format is wanted.

Projects often mix surfaces on purpose: metal for a cooler, contemporary note, stone for weight and solidity, and wood where the elevation should feel warm. Buying facade metal panels direct from manufacturer keeps the panel, the surface approval and the fixing details in one place, which matters most where two surfaces meet at a reveal, a corner or a window head.

Ordering & Delivery

  1. Send your elevation drawings, panel layout, required thickness, surface tone, quantity, site location and target delivery date, so the quotation is built on the real build-up rather than on an estimate.
  2. Confirm minimum order quantity, payment terms and packing with your sales contact. They depend on panel size, surface and destination, so they are set per order rather than from a fixed list.
  3. Plan the programme around production time. Custom orders: 30 days.
  4. Panels are packed for transport in line with the method agreed for the order. Confirm the packing, the unloading arrangement and where the panels will be stored on site before dispatch.
  5. Tell us early whether the metal panels facade is being fixed over a drained cavity or bonded directly to the substrate — it changes what is supplied with the order.
  6. With facade metal panels direct from manufacturer, the surface approval, the panel production and the paperwork sit with one team. Ask your sales contact which test reports and declarations apply to your project.
  7. As exterior metal wall panels suppliers, we handle the export packing and shipping documents for your project, so confirm the delivery terms and the paperwork your site needs.

Fire & Weather Performance

Fire documentation

At approval stage three separate questions usually arrive together, and they are answered separately. The board itself is classified non-combustible at material level, so neither the decorative metal-look face nor the mineral body adds fuel to a fire. Separately again, the wall-panel system as tested reports 90 minutes of fire resistance at 1,200 °C. That second figure belongs to the build-up that was tested, which means panel thickness, substrate, cavity, fixing method and joint detail all sit inside the claim. Tell your sales contact the thickness and the fixing method the project uses, and the report matching that construction is the one issued with the order. Change the thickness or the fixing and the system result has to be re-checked — this is the point where a fire submission usually stalls.

Wind and driving rain

On an exposed elevation, metal facade panels work as part of a tested wall system rather than on their own, and the assembly as tested reports Class 5 air tightness, Class 3 water tightness and wind resistance of plus or minus 6.0 kPa. Because those figures describe the complete construction, the substrate, the cavity, the fixings and the seals carry as much of the result as the board does. A drained and ventilated cavity, correctly sized openings at the base and head of the elevation, and flashing at window heads, parapets and copings are the parts that keep wind-driven rain out. Joints on a drained build-up are normally left open as the drainage and ventilation path; where a closed appearance is wanted, the joint is sealed to an approved detail. Corners, reveals and service penetrations are where water entry begins, so they are detailed before the panel layout is frozen, and fixings are selected for wind uplift against the approved system design. As exterior metal wall panels suppliers we can tell you which report and which detail apply to the elevation you are building.

Humid Interiors & Daily Care

  • Bathrooms, kitchens, balconies and similar humid interiors are part of the board's normal range rather than a special version: the same glass-phase mineral body carries the metal-look face inside and out.
  • The supplied moisture testing reports expansion of 0.1% or less, and the board is tested for mould resistance, which is what makes a wet room a workable specification rather than a compromise.
  • Humidity puts its demands on the whole wall, not only on the panel. Sealing at joints, at cut edges and where the board meets a shower tray, worktop or window reveal is designed with the rest of the build-up.
  • Keep the substrate behind a shower or splashback dry and continuous, and seal the joints to the approved detail. Water standing at a cut edge shortens the life of any board, whatever it is made of.
  • Day-to-day cleaning is mild detergent and water with a soft cloth. Abrasive pads, scouring powders and strong solvent cleaners dull the decorative face and should be kept away from it.
  • Wipe food, oils, coffee and marker marks while they are fresh — a spill left to dry onto the surface is harder to bring back than one wiped straight away.
  • On site, store panels flat on a dry, level surface or on edge in a rack, never on damp ground, and keep them covered until the wall is ready to receive them.
  • The same board that goes up as facade metal panels outside is what goes into a humid interior, so one project can keep to a single panel, a single fixing logic and a single cleaning routine throughout.

Panel Thickness Selection

Wall position Thickness grades Decide before ordering
Exterior wall cladding 10 mm, 12 mm The fixing method — wet bonding, riveting or dry hanging — and the wind exposure of the elevation.
Interior wall lining 4 mm, 6 mm, 8 mm, 10 mm The substrate, the panel size and whether the wall takes everyday impact.
Full series range 4–15 mm across the series The band covers every series, so the wall position decides which part of it you order.
Large panel formats Matched to the grade for the wall position A larger panel loads the substrate and the fixing more, so panel size is confirmed together with the grade, not after it.
Metal panels facade elevations 10 mm, 12 mm Joint width and fixing positions, agreed with the approved detail before anything is cut.
Cut edges and trims Any grade Cut edges expose the mineral body, so trims and sealant follow the approved detail and fixings are placed to the distances set in the system design.

Scale & Supply Capability

CERSAIPANEL is the brand of Yulin Keli Keying Technology Co., Ltd., a building-material manufacturer established in 2016 and based in Yulin, Shaanxi, where we run our own production base with a workforce of 140. Manufacturing and export sit under one roof, so buyers in Europe, North and South America and Australia deal directly with the people who make the goods. Our full range is backed by third-party testing and the international certifications the company holds, and we take on OEM work and custom orders, from first sample through repeat production.

FAQ

What gives this panel its metal look, and does it behave like real metal on a wall?

The metal appearance is a decorative face printed onto the board and cured, not a metal skin bonded to a substrate. There is nothing to polish, oxidise or re-coat, and the surface is stain, scratch and wear resistant. Routine cleaning with mild detergent and water is enough, and aggressive marks are better removed promptly than left to sit.

How is fire performance documented for this panel?

The supplied test material classifies the board as non-combustible at material level, and reports 90 minutes of fire resistance at 1,200 °C for the tested wall-panel system. Those two statements belong to the tested material and the tested construction, not to every possible build-up — a different panel thickness, a different fixing or a different joint detail changes the result, so the exact system is confirmed against your project report and the local code. As exterior metal wall panels suppliers we can tell you which reports apply to the build-up you are planning.

How does the system perform on an exposed, wind-driven facade?

Metal facade panels work as part of a tested wall system rather than on their own. For exterior wall systems the reported values are Class 5 air tightness, Class 3 water tightness and wind resistance of plus or minus 6.0 kPa. Those figures describe the complete assembly, so the substrate, the cavity, the fixings and the sealing detail matter as much as the panel, and correct flashing and drainage remain part of the design.

How consistent are the panels from one batch to the next?

Consistency is held against the approved reference: the surface is a printed decorative face, so production is matched to the signed piece rather than to a colour number. Ordering facade metal panels direct from manufacturer keeps that reference and the production with the same team, so any change in tone or pattern is agreed before the panels are made rather than after they arrive. On a large elevation, keeping the panels within a single production batch gives the most even result.

Can the panel be used in bathrooms, kitchens and other humid interiors?

Yes. The board is offered for interior and exterior work, including bathrooms, kitchens and balconies, and the supplied tests report moisture expansion of 0.1% or less. Humidity still makes demands on the build-up, so the sealing and detailing are worked out with the rest of the wall design rather than left to the panel alone.

How are joints and cut edges finished on site?

Joint treatment follows the system design. On a drained and ventilated exterior build-up the joints are usually left open as part of the drainage and ventilation path; where a sealed appearance is wanted, the joint is sealed to the approved detail. Cut edges expose the mineral body of the board, so they are cleaned of dust and finished with the agreed trim or sealant rather than left raw. On facade metal panels the joint line is also a design line, so the width is set at layout stage and kept consistent across the elevation.

Leave a message
姓名
电子邮件*
信息