The metal-look band of the CERSAIPANEL range is made for elevations that want the depth of a weathered metal surface without the handling and upkeep of an exposed metal skin. The board behind the face is an inorganic fibre panel formed from coal gasification slag, an industrial by-product that is melted twice at 1,500 °C and restructured into a fully glass-phase material. The finished board is formaldehyde-free and benzene-free, with no toxic volatile organic compounds detected in the supplied test information, and the surface you see is a decorative face carried on that mineral body rather than on metal. Metal facade panels from this band go up on exterior walls and interior walls alike — commercial buildings, institutional projects, hotels and high-end residential work.
It is the panel chosen when a project wants an aged metal look without the weight of stone or the upkeep of real metal cladding. Design teams come to it for the surface, contractors come to it because it handles like a dense mineral board that takes the range's normal fixing details, and distributors come to it because it fills a metal-look slot in a range that also covers stone and wood.
| Property | Specification |
|---|---|
| Base material | Inorganic fibre board made from coal gasification slag |
| Material structure | Fully glass-phase, formed by a two-stage 1,500 °C melt |
| Surface | Metal-look decorative face |
| Panel length | Up to 3,050 mm |
| Panel width | Up to 1,220 mm |
| Thickness | 4–15 mm depending on series |
| Apparent density | Approximately 950–1,200 kg/m³ across the range |
| Screw withdrawal strength | At least 1,870 N |
| Site fabrication | Can be cut, drilled, nailed and screwed |
| Test | What it covers |
| Antiviral activity test | Surface behaviour of the finished board |
| Fire resistance test | Performance under controlled flame and heat exposure |
| Mold resistance test | Behaviour in humid conditions |
| Radioactivity test | Natural radioactivity of the mineral content |
| Scrapped-off toy material test | Safety of the surface in contact use |
| VOC test | Volatile organic compound emissions |
The metal surface band runs from CP-MT-001 to CP-MT-006 — six metal looks in the same board system, differing in tone and pattern rather than in substrate or fixing detail. As exterior metal wall panels suppliers, we hold the whole band, so one project can take two or three metal tones across different elevations and still order a single substrate, a single fixing logic and a single set of details. The same board also comes with stone-look and wood-look faces, and the solid aluminium mosaic line covers interior feature walls where a smaller format is wanted.
Projects often mix surfaces on purpose: metal for a cooler, contemporary note, stone for weight and solidity, and wood where the elevation should feel warm. Buying facade metal panels direct from manufacturer keeps the panel, the surface approval and the fixing details in one place, which matters most where two surfaces meet at a reveal, a corner or a window head.
Fire documentation
At approval stage three separate questions usually arrive together, and they are answered separately. The board itself is classified non-combustible at material level, so neither the decorative metal-look face nor the mineral body adds fuel to a fire. Separately again, the wall-panel system as tested reports 90 minutes of fire resistance at 1,200 °C. That second figure belongs to the build-up that was tested, which means panel thickness, substrate, cavity, fixing method and joint detail all sit inside the claim. Tell your sales contact the thickness and the fixing method the project uses, and the report matching that construction is the one issued with the order. Change the thickness or the fixing and the system result has to be re-checked — this is the point where a fire submission usually stalls.
Wind and driving rain
On an exposed elevation, metal facade panels work as part of a tested wall system rather than on their own, and the assembly as tested reports Class 5 air tightness, Class 3 water tightness and wind resistance of plus or minus 6.0 kPa. Because those figures describe the complete construction, the substrate, the cavity, the fixings and the seals carry as much of the result as the board does. A drained and ventilated cavity, correctly sized openings at the base and head of the elevation, and flashing at window heads, parapets and copings are the parts that keep wind-driven rain out. Joints on a drained build-up are normally left open as the drainage and ventilation path; where a closed appearance is wanted, the joint is sealed to an approved detail. Corners, reveals and service penetrations are where water entry begins, so they are detailed before the panel layout is frozen, and fixings are selected for wind uplift against the approved system design. As exterior metal wall panels suppliers we can tell you which report and which detail apply to the elevation you are building.
| Wall position | Thickness grades | Decide before ordering |
| Exterior wall cladding | 10 mm, 12 mm | The fixing method — wet bonding, riveting or dry hanging — and the wind exposure of the elevation. |
| Interior wall lining | 4 mm, 6 mm, 8 mm, 10 mm | The substrate, the panel size and whether the wall takes everyday impact. |
| Full series range | 4–15 mm across the series | The band covers every series, so the wall position decides which part of it you order. |
| Large panel formats | Matched to the grade for the wall position | A larger panel loads the substrate and the fixing more, so panel size is confirmed together with the grade, not after it. |
| Metal panels facade elevations | 10 mm, 12 mm | Joint width and fixing positions, agreed with the approved detail before anything is cut. |
| Cut edges and trims | Any grade | Cut edges expose the mineral body, so trims and sealant follow the approved detail and fixings are placed to the distances set in the system design. |
CERSAIPANEL is the brand of Yulin Keli Keying Technology Co., Ltd., a building-material manufacturer established in 2016 and based in Yulin, Shaanxi, where we run our own production base with a workforce of 140. Manufacturing and export sit under one roof, so buyers in Europe, North and South America and Australia deal directly with the people who make the goods. Our full range is backed by third-party testing and the international certifications the company holds, and we take on OEM work and custom orders, from first sample through repeat production.
The metal appearance is a decorative face printed onto the board and cured, not a metal skin bonded to a substrate. There is nothing to polish, oxidise or re-coat, and the surface is stain, scratch and wear resistant. Routine cleaning with mild detergent and water is enough, and aggressive marks are better removed promptly than left to sit.
The supplied test material classifies the board as non-combustible at material level, and reports 90 minutes of fire resistance at 1,200 °C for the tested wall-panel system. Those two statements belong to the tested material and the tested construction, not to every possible build-up — a different panel thickness, a different fixing or a different joint detail changes the result, so the exact system is confirmed against your project report and the local code. As exterior metal wall panels suppliers we can tell you which reports apply to the build-up you are planning.
Metal facade panels work as part of a tested wall system rather than on their own. For exterior wall systems the reported values are Class 5 air tightness, Class 3 water tightness and wind resistance of plus or minus 6.0 kPa. Those figures describe the complete assembly, so the substrate, the cavity, the fixings and the sealing detail matter as much as the panel, and correct flashing and drainage remain part of the design.
Consistency is held against the approved reference: the surface is a printed decorative face, so production is matched to the signed piece rather than to a colour number. Ordering facade metal panels direct from manufacturer keeps that reference and the production with the same team, so any change in tone or pattern is agreed before the panels are made rather than after they arrive. On a large elevation, keeping the panels within a single production batch gives the most even result.
Yes. The board is offered for interior and exterior work, including bathrooms, kitchens and balconies, and the supplied tests report moisture expansion of 0.1% or less. Humidity still makes demands on the build-up, so the sealing and detailing are worked out with the rest of the wall design rather than left to the panel alone.
Joint treatment follows the system design. On a drained and ventilated exterior build-up the joints are usually left open as part of the drainage and ventilation path; where a sealed appearance is wanted, the joint is sealed to the approved detail. Cut edges expose the mineral body of the board, so they are cleaned of dust and finished with the agreed trim or sealant rather than left raw. On facade metal panels the joint line is also a design line, so the width is set at layout stage and kept consistent across the elevation.