• CP-ST-001,MY SHOP,CP-ST-001
  • CP-ST-001,MY SHOP,CP-ST-001

CP-ST-001 Stone-Texture Inorganic Fibre Facade Board

Stone-look inorganic fibre board for exterior facades and interior walls, up to 3,050 x 1,220 mm, from the same range as our facade metal panels.
  • CP-ST-001,MY SHOP,CP-ST-001

Description

Product Overview

CP-ST-001 is a stone-texture board from the CERSAIPANEL range: a rigid, fully inorganic fibre panel with a printed stone face — a pale marble field crossed by grey and charcoal veining. It is made for walls that are specified as panels rather than slab. An exterior elevation, a ground-floor base, an entrance or a lobby wall where a stone look is wanted, in a format that is set out, fixed and replaced board by board.

Panels are flat and rigid, supplied in long formats that cover a facade bay with few joints, and in shorter cuts for returns, soffits and column casings. The thickness that suits a given wall is settled at specification stage, because it follows the substrate, the fixing method and the exposure rather than the surface alone.

Day to day the material behaves like a facade panel: it is set out on a grid, fixed to a prepared background or a subframe, and replaced as an individual board if one is damaged. Nothing about working with it needs a specialist fabricator.

Buyers arrive at this surface from two directions. Some are specifying a stone look for the first time and want to know how it behaves next to real stone. Others already run a facade package and need a material that matches at the base or inside the entrance. The stone, metal and wood surfaces are all made on the same site, so a project that buys facade metal panels direct from manufacturer can add stone-look boards to the same order without opening a second supply line.

Stone Surface & Finish

  • Marble field with grey and dark veining. The face reads as a pale stone field crossed by grey and charcoal veins, printed at panel scale rather than tile scale, so a wall carries one continuous stone figure instead of a grid of repeats.
  • A smooth, polished face. This is a polished stone look on a flat surface, not a rough-cast or split-face texture. It suits elevations and interiors where the architecture wants a clean, reflective finish rather than a rustic one.
  • Surface behaviour. The decorative surface is stain, scratch and wear resistant, which is what keeps a stone look presentable in entrances, corridors and other zones that are touched and washed often.
  • Consistent finish across the range. Colour depth and gloss are controlled on the same printing line as our facade metal panels and wood-look boards, so a specification that mixes surfaces does not read as a patchwork of different materials.
  • Custom stone patterns. Beyond the standard stone looks, patterns can be produced with 3D high-definition printing and electron-beam curing. Send the stone you are matching or a reference image, and we will confirm what the line can reproduce for that pattern.
  • Veining across joints. Where the veining has to run continuously along a wall, raise it at layout stage. Agree with us how the pattern is sequenced across the panels before production, rather than discovering the joint lines on site.
  • Matching an existing wall. When boards are added to a wall that already carries panels, compare against an installed panel or an approved physical sample rather than a screen image, because colour shifts from monitor to monitor and from screen to daylight.

Specifications

Property Value
Surface Printed stone look — pale marble field with grey and dark veining
Board material Inorganic fibre board made from coal gasification slag
Panel length Up to 3,050 mm
Panel width Up to 1,220 mm
Thickness 4 mm to 15 mm across the range; exterior walls are normally specified at 10 mm and 12 mm, interior walls at 4, 6, 8 and 10 mm
Density Approximately 950–1,200 kg/m³, or higher depending on the product series
Moisture expansion 0.1% or less, on the supplied test information
Screw withdrawal strength At least 1,870 N, on the supplied test information
Fire performance The supplied test information reports Class A non-combustible material behaviour, and 90 minutes at 1,200 °C for the tested wall-panel system
Smoke toxicity Class t0, on the supplied test information
Exterior system performance Class 5 air tightness, Class 3 water tightness and wind resistance of ±6.0 kPa, on the supplied test information
Fixing methods Wet bonding, riveting, dry hanging
On-site fabrication Can be cut, drilled, nailed and screwed

Material & Build

The board behind this surface is an inorganic fibre panel made from coal gasification slag — an industrial solid waste that used to be stockpiled and could not be broken down. We melt it twice at 1,500 °C and rebuild the mineral structure, so the finished board is a fully vitreous, glass-phase material rather than a resin-bonded composite. The same core sits behind our metal panels facade and wood-look boards; the series differ by surface, not by material. If you have seen the product name translated as carbon fibre board, that is not what this is: it is not a carbon-fibre-reinforced polymer composite, and it is not natural stone or fired ceramic.

That origin has three consequences a project can use. The board is inorganic, so the supplied test information reports it as formaldehyde-free and benzene-free, with no toxic volatile organic compounds detected — which matters where indoor air quality is part of the brief, such as schools, hospitals and residential interiors. It is dense and rigid rather than soft, so it behaves like a panel on site, holds fixings and takes a knock without the brittleness of a thin tile. And the melting process runs on wind and solar electricity, so production uses green power rather than fossil generation — worth knowing when a project carries an embodied-carbon target.

Where this board is compared with stone slab, ceramic tile and several traditional panel systems, it is the lighter option, which reduces the load the structure has to carry and the handling equipment needed on site. That is a comparison against the materials it replaces, not a claim about a single figure — the load calculation still belongs to your engineer.

What the material does not decide on its own is how it performs on your wall. Fire, weather and moisture results belong to a tested construction — panel specification, substrate, subframe, joints and fixing method together. Send us the wall build-up you are working to, and we will confirm which of the supplied reports applies to it and which documents can be released for the submission.

Applications & Wall Zones

  • Exterior facade cladding. Long panels cover a bay with few joints, and the printed stone field gives the elevation a stone reference. On elevations where the upper volume runs our metal facade panels, the base can run this stone-look board.
  • Ground-floor bases and entrance zones. The zone that is touched, pushed against and washed down is exactly where a stone look has to stay presentable, and where panel replacement has to be simple.
  • Wet and humid interiors. Bathrooms, kitchens and balconies are within scope. The material is inorganic and dimensionally stable in damp service; the detailing that matters is sealing, flashing and drainage, not the panel itself.
  • Public and institutional interiors. Schools, hospitals, airports, rail and transit stations, museums — long wall runs, high traffic and an expectation of straightforward cleaning.
  • Feature walls and reception areas. A veined marble reading works well on a tall single wall, where a printed pattern is an advantage because the figure can be repeated predictably instead of varying slab to slab.
  • Buildings whose outward language is metal. On industrial, infrastructure and service buildings where the elevation is defined by a metal panels facade, the base, the entrance and the interior walls often want a stone reference instead, and the surface change is the only change.
  • Marine and ship interiors. Cabin linings and interior partitions are part of the application list, where the fire and finish documentation has to be checked against the classification requirement for the vessel.
  • Ceilings, partitions and cabinet faces. The board can be worked into ceilings, partitions and cabinet fronts as well as walls; thickness and fixing follow the same logic as a vertical application.

Fixing Methods

  1. Set out from the approved drawings first. Confirm the panel grid, the joint width and the fixing method before anything is ordered, because the substrate, the wall height and the exposure decide whether the job is bonded, riveted or dry hung. The chosen method must follow the approved system design for the project.
  2. Wet bonding. Adhesive onto a flat, prepared and stable background. This is the usual approach indoors, where the wall is true and access is easy, and it keeps the finished face flush.
  3. Riveting. Mechanical fixing through the panel onto a subframe, used where the panel has to be held positively rather than by adhesion alone, and where a fixing point can be seen and inspected.
  4. Dry hanging. A carrier system with a drained, ventilated cavity behind the panel. It is the approach for large facades and the one most crews already know from dry hanging a metal panels facade, so the sequence feels familiar on site.
  5. Subframe and setting out. Allow adjustment in the same way as behind any facade metal panels rainscreen. The panel face is flat and rigid, so any unevenness in the substrate shows in the finished wall rather than being absorbed by the board.
  6. Cutting and drilling on site. The board can be cut, drilled, nailed and screwed with standard tools. Support the panel on both sides of a cut, keep the surface clean while working, and leave any transit protection in place until the wall is finished.
  7. Joints, sealing and drainage. Joint width, sealant and flashing come from the system design. On exterior work water has to reach the cavity and leave it again — a sealed joint with nowhere to drain is the most common source of call-backs on any panel facade.
  8. Check the finish before sign-off. Walk the wall in daylight and at an angle, and check alignment, joint consistency and panel-to-panel colour before the scaffolding comes down, so any adjustment is made while access is still there.

Ordering & Delivery

  • Lead time. Custom orders: 30 days, counted from the point the specification, the surface and the quantity are confirmed.
  • Minimum order quantity. MOQ is confirmed per surface and per format rather than fixed across the range, so ask your sales contact for the figure that applies to your panel size and finish.
  • What to send with an enquiry. The application, panel size and thickness, surface finish, quantity, project location and the delivery date you are working to — plus the wall drawings or the intended fixing method if it is already decided. The more of this arrives at the start, the closer the first quotation is to something you can use.
  • Samples. Physical samples are arranged through the sales team so the stone surface can be judged against the material it will sit next to. Ask your sales contact about sample availability and how a sample is prepared from your reference image.
  • Packing and transport. Panels are normally supplied on pallets with edge protection and interleaving, so faces do not rub against each other in transit. Confirm the packing standard and the shipping arrangement that apply to your size, quantity and destination.
  • Documents. Tell us which test reports or declarations the submission needs. Availability depends on the document and the market, and we will confirm what can be issued for your project.
  • Payment and delivery terms. Payment terms, delivery terms and any inspection arrangement are agreed with your sales contact before production starts.
  • Mixed-surface packages. Where an elevation combines surfaces, stone-look boards and metal panels can be produced and packed together. A project that wants to buy facade metal panels direct from manufacturer does not have to place the stone zones with a second supplier.
  • Buying the whole elevation. Buyers who have previously dealt only with exterior metal wall panels suppliers can put the entire facade package on one order — metal, stone and wood surfaces, one set of panel layouts and one delivery to site.

Surface Range & Selection

The three surface families answer three different briefs. Stone-look boards, this series, are chosen where the architecture needs a stone reference: large facade fields, ground-floor bases, entrance zones and lobby walls. Metal-look boards give a cleaner, more uniform surface for contemporary volumes, soffits and service zones, and where the design language is metal our metal facade panels carry the same board with a metal finish. Wood-look boards bring a warm timber reference to interiors, soffits and feature zones, without the moisture and upkeep concerns that come with real timber.

Choosing between them is usually a question about the zone rather than about the whole building. It is common for one elevation to run a metal surface above and a stone-look base at street level, or a stone-look facade outside with a wood-look wall inside the same entrance. Because the surfaces share a board and a fixing logic, the surface can change without changing how the wall is built — but the joint widths, the panel module and the thickness should be agreed across that change, not decided surface by surface.

If you are specifying metal and stone together — buying facade metal panels direct from manufacturer for the upper elevations and stone-look boards for the base — fix the panel module first and let both surfaces follow it. Send us the stone or the reference image you are matching, and tell us which zones take which surface. We will confirm what the line can reproduce and how the two surfaces meet at the transition.

Thickness & Panel Planning

  • Thickness follows the wall rather than the surface. The same stone look is supplied across the full range, and the tier a project uses is set by the substrate, the fixing method, the exposure and the span between fixing points. Settle the tier with us before the panel layout is frozen.
  • Measure the actual opening. Work from the built wall rather than from the drawing: bay width, height to the structural line, and the returns. Take every dimension at several points, because a bare frame is rarely square, and plan the panel module so that variation is absorbed in the joints instead of at the edges.
  • Fix the module before the panel size. Joint width and panel module decide how the wall reads, and the panel length then follows. Long boards cover a bay with few joints; shorter cuts are easier to handle and are the practical choice for soffits, ceilings, column casings and any zone with restricted access.
  • Check the span between fixings. The board has to be supported closely enough that it does not flex under wind or impact. If the subframe spacing is already fixed by the system design, send it with the enquiry so the thickness can be checked against it.
  • Step up a tier where the wall earns it. Wind on a high elevation, impact at street level, or the need for a stiffer board to hold the joints straight all argue for the heavier tiers. An interior wall bonded to a flat background rarely needs what an exterior elevation does.
  • Leave tolerance for the cut. Add a small allowance to every measured panel for the saw kerf, and place cuts where the finished edge ends up behind a trim, a cover strip or a sealed joint. Cut and drill with the face supported on both sides.
  • Mixing tiers in one elevation. Where the base runs a heavier board and the field above is the same surface in a lighter tier, agree the surface depth at the transition so the change reads as a detail, and keep the module identical across both zones.
  • Plan for the weight. A full-format panel in the heavier tiers is a two-person lift. Work out lifting equipment, site access and how many panels can be handled in a day before the installation programme is fixed.

Moisture, Mould & Cleaning

The board itself is inorganic, so there is nothing in it for mould to feed on: no cellulose, no wood flour and no organic binder in the core, and a glass-phase structure that does not soften or swell in damp service. The supplied test information reports moisture expansion of 0.1% or less. If the submission needs the water-absorption figure for this board, ask your sales contact and we will confirm which figure belongs to your specification.

Where mould appears on a wall like this, it usually starts in the construction rather than in the panel — a joint that traps water, a cavity with no drainage, a substrate that stays wet behind a bonded board, or a dirt film holding moisture on the face. Sealing, flashing, drainage and ventilation are what keep a bathroom, kitchen, balcony or laundry wall clean, and the board's part is to stay flat and stable while the rest of the build-up does its work.

Cleaning needs no specialist products. Wipe with a soft cloth or soft brush and a mild neutral cleaner, then rinse or wipe dry. Entrance bases, corridors and washroom walls are touched and washed far more often than an upper elevation, so put them on a routine round instead of waiting for the wall to look tired. Oil, ink and sealant smears come away most readily when they are dealt with promptly, and hard-water marks usually respond to repeating a mild clean rather than to a strong descaler.

What to avoid: abrasive pads, wire wool, gritty creams and strong solvents, all of which dull a printed or polished face faster than they lift the mark. Test any new cleaning product on an offcut before it goes near a finished wall, and use a plastic scraper rather than a metal one on anything stuck to the surface. Sealant joints and flashings are the first things to age on any wall, so check them on the same maintenance round as the panels — most damp problems start at a joint, not at a board face.

Upkeep is where the comparison with real stone and ceramic shows. There is no sealing round, no re-polishing and no efflorescence to wash off, and where a stone wall might be re-faced after damage, here the affected board is replaced on its own. Keep two or three boards from the project batch flat and dry in store: if the surface is disturbed later, a replacement from the same production run blends into the wall around it. On site, keep panels off damp ground and out of standing water, and leave the protective film in place until the wall is finished.

Model Code & Colour Matching

What to confirm How to check it Why it matters
Model code CP-ST-001 on the drawing, the order and the packing list The code identifies the board and its stone surface together, so the quotation, the approved sample and the delivered panels all refer to the same product.
Surface series Confirm the stone-look series against the approved sample The range also covers metal-look and wood-look surfaces, and each series carries its own pattern references. List mixed elevations by code rather than by colour name.
Colour and pattern Approve a physical sample and keep it as the project reference Printed surfaces are checked against the approved sample before packing; a screen image shifts between monitors and again in daylight.
Other stone textures CP-ST-002 to CP-ST-032 are separate stone looks in the same family If the wall calls for a different stone figure, order that code instead of expecting a colour change on this one.
Thickness tier State the tier on the order The code does not carry the thickness; the wall, the substrate and the fixing method decide it.
Neighbouring surfaces List the other surfaces on the elevation by code as well Where facade metal panels run above a stone-look base, ordering the whole elevation as one reference set keeps the module, the joint widths and the surface depths aligned.
Later additions Quote the original model code and, if you have it, the original order or batch reference A later run is produced to the same specification, and the closest match to an installed wall comes from the same code and, where possible, the same production run.

Scale & Supply Capability

CERSAIPANEL is the brand of Yulin Keli Keying Technology Co., Ltd., a building-material manufacturer established in 2016 and based in Yulin, Shaanxi, where we run our own production base with a workforce of 140. Manufacturing and export sit under one roof, so buyers in Europe, North and South America and Australia deal directly with the people who make the goods. Our full range is backed by third-party testing and the international certifications the company holds, and we take on OEM work and custom orders, from first sample through repeat production.

FAQ

How do I choose between the exterior and interior thickness tiers?

It follows the wall rather than the surface. Exterior work uses the heavier tiers, because the panel has to span between fixings and take wind load on a drained cavity. Interior walls can use the lighter tiers and are often bonded straight onto a flat background. Your substrate, the fixing method and the exposure decide the number, so send us the wall section and we will confirm the thickness that applies before the drawings are frozen.

Will the delivered panels match the sample I approve?

Production is run against the approved sample, and the printed surface is checked for colour and pattern consistency before packing. Two things make that reliable: approve a physical sample rather than a screen image, and keep it as the reference for the project. If the new boards have to sit beside a wall that is already installed, say so at the enquiry stage so the match can be assessed against an existing panel.

How should the surface be cleaned?

Wipe with a soft cloth or soft brush and a mild neutral cleaner, then rinse or wipe dry. Aggressive stains — oil, ink, sealant smears — should be removed promptly rather than left to sit. Avoid abrasive pads, wire wool and strong solvents, and test any new cleaning product on an offcut before using it across a finished wall.

What happens if a panel is damaged on site?

The boards are individual units, so a damaged panel can usually be cut out and replaced without redoing the surrounding wall. How cleanly it comes away depends on the fixing method: riveted and dry-hung panels release from the subframe, while bonded panels take some of the adhesive with them. Check deliveries before installation begins and report any transit damage with photographs, so it is dealt with before the wall is closed up.

Do you supply the metal-look and wood-look surfaces as well?

Yes. We are exterior metal wall panels suppliers as well as producers of the stone-look and wood-look boards, and all three series come off the same production base in Shaanxi. A project can therefore take a single surface or the whole elevation from one base, with the same thickness logic and the same fixing advice behind it.

Can this board be installed next to a metal facade?

Yes, and it is a common arrangement. Where the metal facade panels and the stone-look boards meet, treat the change as a joint detail: agree the joint width, the panel module and the surface depths on the drawing, and the two materials read as one elevation rather than as two systems. Send the transition detail with your enquiry and we will check it against the fixing method you are using.

Leave a message
姓名
电子邮件*
信息