• CP-ST-027,MY SHOP,CP-ST-027
  • CP-ST-027,MY SHOP,CP-ST-027

CP-ST-027 Stone-Texture Facade Panel

Stone-texture inorganic fibre board for exterior and interior walls: polished onyx-style face, 4–15 mm, wet-fix, rivet-fix or dry-hang installation.
  • CP-ST-027,MY SHOP,CP-ST-027

Description

Stone Texture & Surface Finish

A close look at this panel shows a green onyx-style surface: a pale green ground crossed by cream-white and golden-brown veining, finished with a polish that gives the face a glossy, mineral depth. None of it is quarried. The stone look is produced on the board itself, so the pattern you approve is the pattern that runs across the elevation, without the block-to-block variation that comes with natural slabs.

Because the surface is made rather than cut, a project can ask for a specific stone and work to it. Send us the reference — a photograph of the stone, a finish already used on another elevation, or a physical sample — and we produce to a colour code rather than to a general "stone" description. Confirm that code against the approved sample before production, and keep each elevation to panels from the same production run so the field reads as one surface from the ground to the parapet.

The finish behaves differently according to where it is used. In direct sun the polish picks up the light and the veining reads more strongly; on a shaded or north-facing wall the same panel looks deeper and calmer. Indoors, under artificial light, the surface sits closest to the reference image. On a project where the look matters, check the panel in the light it will actually be seen in before the whole elevation is drawn into the order.

Direction matters on a large field. The veining is a designed pattern, not a repeating tile, so decide which way it should run and record that on the layout drawing before anything is cut. On a wide elevation, set the joint grid out first and let the pattern fall inside it rather than letting the pattern dictate where the joints land; the same drawing then carries the setting-out for the fixings.

This is the surface to choose when an elevation needs the weight and familiarity of stone. It sits comfortably beside exterior metal facade panels, timber and brick, and it reads as a stone finish both at the distance a passer-by sees it and at the distance a visitor stands from the entrance wall.

Material & Composition

  • Made from an industrial by-product: the base material is coal gasification slag, a solid residue from coal gasification that would otherwise be stockpiled. We melt and restructure it in two stages at 1,500 °C and rebuild it as a mineral sheet.
  • Fully glass-phase and inorganic: the finished board is vitreous — not a resin-bonded panel and not a carbon-fibre-reinforced composite, whatever class name the material is sometimes filed under.
  • Formaldehyde-free and benzene-free: the supplied test information reports no toxic volatile organic compounds detected, which is what makes a board of this kind usable in school, hospital and residential interiors.
  • Nothing in it for mould to feed on: an inorganic sheet offers mould no nutrient, and mould resistance forms part of the performance tested on this material.
  • Low weight for a stone appearance: a panel of this type is considerably lighter than natural stone or ceramic tile of a comparable look, which reduces dead load on the structure and makes the sheets easier to handle, cut and fix on site.
  • One substrate behind several looks: the sheet we finish as metal exterior wall panels is the same sheet behind this stone texture and the wood-look band, so a building that mixes finishes keeps one substrate and one set of handling rules.
  • Made on our own line: we are among the exterior metal wall panels manufacturers that run their own base sheet, so surface finish, thickness and edge detail can be held consistent across the different looks used on one project.

Specifications

Property Value
Product code CP-ST-027
Panel type Inorganic fibre decorative board
Surface Polished stone-look pattern
Length Up to 3,050 mm
Width Up to 1,220 mm
Thickness 4–15 mm; exterior walls typically 10 mm or 12 mm, interior walls 4, 6, 8 or 10 mm
Density Approx. 950–1,200 kg/m³ depending on series
Moisture movement 0.1% or less
Screw withdrawal At least 1,870 N
Fire classification Class A non-combustible (material classification)
Surface durability Stain, scratch and wear resistant
Colour Stone-look; pattern set by the selected code

Applications & Wall Positions

  • Large façade fields on commercial buildings: long, flat elevations where a stone texture gives the building weight; panels are set out on a joint grid, cut to the layout and fixed to the project's system design.
  • Entrance zones and feature bays: the veining reads clearly at close range, so this surface suits reception walls, entrance surrounds and the first bay of an elevation, where people see it as they arrive.
  • Mixed-finish elevations: where a scheme puts this stone texture on the main field and exterior metal wall panels on a contrasting bay, both are cut and fixed with the same tools and the same joint logic, so one crew can run the whole elevation.
  • Institutional interiors: schools, hospitals, airports, rail stations and museums use boards of this type for corridor, concourse and waiting-area walls, where a surface has to look finished and stay easy to clean.
  • Wet interior areas: bathrooms, kitchens and balconies in hotels, apartments and offices, with the joints, edges and fixings detailed for the moisture they will see.
  • Ceilings, partitions, doors and cabinet fronts: the same board is used for interior joinery and ceiling work, fixed with the method the substrate calls for.
  • Shopfitting and display: store interiors, display cabinets and reception desks, where a stone look is wanted without a stone weight.
  • Distributor ranges: importers and regional agents who serve their own market as an exterior wall panels supplier can hold this stone texture alongside the metal-look and wood-look bands, so their customers choose a complete finish set from one range.

Installation & Fixing Methods

  1. Confirm the wall and the fixing method — exterior walls use one of three site-established routes: wet bonding, riveting or dry hanging. The route follows the substrate, the wall height and the approved system design for the project.
  2. Agree the layout before anything is cut — set out the panel grid, the joint width and the direction the pattern runs on a drawing, including where the elevation turns a corner or meets another material.
  3. Cut and drill to that drawing — the board is worked like a panel rather than like stone: it can be cut, drilled, nailed and screwed, and the cut edges are finished to the joint plan. Support the sheet while cutting so it does not flex or crack.
  4. Dry-fit the first section — lay panels up unfixed and check joint lines, pattern continuity and the transition to adjacent finishes before committing to adhesive or fixings.
  5. Fix to the approved schedule — adhesives, brackets and fixings are used exactly as the system design specifies. On a ventilated façade the panel is carried by the sub-frame rather than bonded to a wet wall, the same arrangement exterior metal wall panels manufacturers use on this kind of build-up.
  6. Detail the joints, flashings and drainage — correct sealing, flashing and drainage are what keep an exterior wall dry; interior walls need clean, properly sealed joints at wet areas.
  7. Clean down and protect — remove adhesive residue and handling marks while they are still fresh, and keep the finished face masked or boarded while other trades are working nearby.
  8. Record what was built — photograph the as-built joints and note the fixing schedule; it makes a later repair, extension or second phase straightforward.

Fire Performance & Documentation

The fire question has three separate parts, and they are worth separating before anything goes into a submission: how the decorative surface reacts, how the board material itself behaves, and how the finished wall construction performs. The material classification belongs to the board on its own. The ninety-minute result our tested wall-panel system is documented at, at 1,200 °C, belongs to a specific assembly — panel, substrate, joints and fixings together. Change any one of those and the figure no longer describes your wall, which is why we ask for the build-up before pointing anyone at a report.

Smoke behaviour is reported separately again, as Class t0, with no toxic volatile organic compounds detected. On an escape route or in a public interior that line usually matters as much as the fire rating itself, and it is one of the reasons institutional projects specify inorganic boards rather than polymer finishes.

We can hand over third-party test reports covering fire resistance, mould resistance, VOC emissions and radioactivity, and direct you to the ones your submission needs. What makes that pack accurate is the information you send us: the wall build-up, the substrate, the joint widths, the fixing method and the market you are building to. Approvals are granted locally by the authority or consultant reviewing the project — our job is to make sure the documents describe the wall that is actually being installed.

One practical note: keep the fire documents on the same drawing revision as the fixing details. Assemblies change late in a programme more often than anyone expects, and a report that no longer matches the as-built build-up is worth very little at handover.

Cleaning & Site Handling

  • Routine cleaning: warm water with a neutral cleaner and a soft cloth or mop is enough. Wipe in one consistent direction and rinse, rather than scrubbing at a mark and spreading it.
  • Deal with stains early: prompt removal of aggressive stains — coffee, oil, marker, construction residue — is the recommended practice; the longer a stain sits on a polished face, the more work it takes to lift.
  • What to keep off the surface: abrasive pads, scouring powders, strong solvents and acidic cleaners dull a polished face. Keep them away from the panels, the trims and the joints.
  • One routine across the range: the neutral-cleaner wipe-down we recommend for exterior metal facade panels and wood-look boards applies here too, so a mixed-finish building needs only one maintenance instruction.
  • Site protection: keep panels covered until they are fixed, stack them flat on battens clear of the ground, and carry sheets on edge rather than flat to avoid flexing them.
  • Separate the trades: masking or boarding the finished face while wet trades, welding or painting continue nearby prevents most of the marks that end up on a completed wall.
  • Cutting and drilling: work in a ventilated area, use dust extraction where possible and wear a mask; the dust is inorganic, but it is still dust.
  • After handover: pass the cleaning routine to the facility or maintenance team as part of the handover file, so the surface is looked after the same way across its service life.

Range & Related Finishes

This panel belongs to the stone-texture band of the range — a run of codes covering stone looks from fine, even grain through to bold, high-movement patterns such as the onyx-style surface on this product. When a project wants a different stone character on a secondary elevation, or a quieter surface inside a lift lobby, the same band is where to look: the setting-out, thickness family and fixing methods stay the same while only the pattern changes.

The range does not stop at stone. The metal-look band produces the surfaces we supply for exterior metal wall panels, and the wood-look band gives a warm timber appearance without timber's moisture and maintenance behaviour. All three use the same inorganic sheet, and that matters more than it sounds: a mixed façade can be drawn once, on one thickness family, with one fixing logic and one set of handling rules, instead of three packages that have to be coordinated on site.

Choosing between them usually comes down to what an elevation has to say. Stone reads as mass and grounding — good for the base of a building, the main field, or a wall that should feel permanent. Metal reads crisp and technical and suits long horizontal runs, entrance reveals and industrial or transport buildings. Wood-look warms a surface and works well on soffits, canopies and interior walls where people come close enough to touch it.

A fourth line sits alongside these three. The aluminium mosaic range is a decorative interior product for feature walls, reception areas and washrooms, specified for its pattern. It is a different job from the boards on this product and should not be read as a façade or fire-rated panel.

Ordering & Delivery

  1. Send the project details — wall position, exterior or interior; panel size and thickness; surface finish; quantity; project location; and required delivery date. Those six points are what we need as an exterior wall panels supplier to come back with a grade, a colour code and a price.
  2. Confirm the colour before production — if the design hangs on a particular stone, approve the colour code first, and tell us whether two elevations have to match each other or match a finish already on site.
  3. Ask about samples and documents — your sales contact can confirm sample availability, and, once the specification is fixed, which test documents apply to your project.
  4. Lead time — Custom orders: 30 days.
  5. Minimum order, payment, packing and shipping — confirm the minimum order quantity, payment terms and the packing and shipping arrangement with your sales contact, as these are set for the order and the destination.
  6. Plan the delivery against the programme — tell us how the site is sequenced. If an elevation is completed in stages, deliveries are planned to match that sequence rather than arriving in one drop.

Exposed Walls & Fixing Strength

  • On a sheltered wall — a recessed bay, a courtyard, an interior partition or a face standing behind a taller structure — the fixing is usually straightforward: bond or rivet the panel to a properly prepared substrate, and wind never becomes the governing load.
  • On an exposed or high wall the load reverses. Wind suction tries to pull the panel off the wall, and it grows with height, with the openness of the surroundings and with the position on the elevation, so the fixing has to be mechanical — rivet-fixed to a sub-frame, or dry-hung on brackets sized for the load.
  • Send the engineer's figures with your enquiry: wall height, the building's location and exposure, the wind pressure for that elevation, the substrate behind the panel and the fixing method already approved. Bracket type, bracket spacing and the fixing pattern follow those numbers.
  • Thickness and fixing strength go together. A 10 mm or 12 mm exterior panel takes a fixing better than a 6 mm interior sheet, so settle the panel gauge before the fixing layout is drawn. Ask us for the pull-out value and the test document that covers the thickness you are specifying.
  • Keep the fixings where the schedule puts them — in from the panel edge and corner rather than close to it — drill pilot holes to the agreed size, and tighten washer-head screws until the panel is held, not crushed.
  • Allow the panel to move. Temperature and humidity change the sheet slightly, so joints and slotted fixings need room for that movement on long runs and on dark surfaces facing strong sun.
  • Treat the elevation by zone. Corners, the top edge, parapets and the areas around openings take more suction than the middle of a field, and bracket spacing is normally tightened there.
  • On a ventilated build-up, the same bracket-and-rail logic that carries metal exterior wall panels carries this stone-texture face; what changes is the surface, not the support behind it.

Moisture & Mould Resistance

The board itself is inorganic and fully glass-phase — no timber, no gypsum core, no resin binder — so it does not take up water and swell the way organic sheets do, and it offers mould nothing to feed on. Mould resistance forms part of the performance testing on this material, and that report can be released to your project.

Water absorption is a material figure rather than a wall figure, and it should be read against the thickness you are specifying. Ask your sales contact for the absorption value and the test method behind it for your panel gauge, and keep that document with the fixing and fire papers in the same submission. Where the panel faces weather as part of a ventilated exterior metal wall panels build-up, the cavity and its drainage do the weather work; the panel is the rain screen, and the waterproofing line stays behind it.

For wet interior areas — bathrooms, kitchens, balconies, washrooms, hospital and school sanitary zones — the panel is a finish, not the waterproof layer. Seal the joints and the cut edges with the sealant the detail calls for, fix to a substrate suited to a wet room, and keep the falls and drainage working behind the finish.

If mould ever appears on a wall finished this way, look at the build-up first: trapped moisture, a cold bridge, a blocked cavity or poor ventilation are the usual causes, and the panel is rarely the source. Keeping the cavity clear, the joints sealed and the substrate dry is what holds the surface clean over its service life.

Scale & Supply Capability

CERSAIPANEL is the brand of Yulin Keli Keying Technology Co., Ltd., a building-material manufacturer established in 2016 and based in Yulin, Shaanxi, where we run our own production base with a workforce of 140. Manufacturing and export sit under one roof, so buyers in Europe, North and South America and Australia deal directly with the people who make the goods. Our full range is backed by third-party testing and the international certifications the company holds, and we take on OEM work and custom orders, from first sample through repeat production.

FAQ

Is this a quarried stone slab or a manufactured panel?

It is a manufactured panel — an inorganic fibre board made from coal gasification slag, melted and restructured in two stages at 1,500 °C, with the stone pattern produced on its face rather than cut from a block. Because the material is inorganic and vitreous, it is not a resin, polymer or carbon-fibre-reinforced composite, and it does not carry the variation of a quarry: the pattern you approve is the pattern that runs across the elevation. This stone-texture band and the metal-look surfaces sit on the same board, which is why we are among the exterior metal wall panels manufacturers producing both.

Can the stone pattern be matched to a reference stone from the project?

Yes. Send us the reference — a photograph, a sample of the stone it has to sit beside, or a finish already used on another elevation — and the pattern is produced on the board with high-definition 3D printing and electron-beam curing. The closer the match needs to be, the more useful a physical reference is, because screens and print shift greens and browns considerably. If the stone texture is going next to exterior metal facade panels or a timber finish on the same scheme, include that in the same conversation, so the tone relationship between the two is agreed before production rather than on site.

Can the same panel be used indoors and outdoors?

Yes — the board is made for both, and it is the same sheet we supply as metal exterior wall panels and wood-look boards. What changes is the detailing around it. Exterior walls need the fixing method, sealing, flashing and drainage set out in the project's system design, and the joints have to be arranged to shed water. Interior walls are simpler: the same panel goes onto the prepared substrate, with sealed joints where the wall is wet. Tell us where the panel is going and we will set the specification accordingly.

How do I avoid visible pattern repetition across a large elevation?

By setting it out on a drawing before the panels are cut. Decide the direction the veining runs, place the joint grid so the joints read as part of the design, and work out the order in which panels are set out so similar areas of pattern are not fixed next to each other. On a long field it helps to review the first section once it is up, before the rest of the elevation follows, and to keep each elevation to panels from a single production run so the tone does not step from one end to the other.

Can this stone texture sit beside your metal-look and wood-look panels on one elevation?

Yes, and it is a common way to use the range. The metal-look faces we supply as exterior metal wall panels, and the wood-look boards, are produced on the same inorganic sheet at the same thickness options, so a scheme can move from a stone field to a metal entrance reveal without changing substrate or fixing family. Agree the joint and the transition trim where the two finishes meet, and check both against the same setting-out drawing so the thicknesses line up on site.

Does a high or exposed wall need a different fixing?

Uplift and wind load decide the fixing on an exposed or high wall, and mechanical fixing — riveting, or dry hanging on a sub-frame — is normally used there rather than bonding alone. Send the wall height, the exposure, the substrate and the project engineer's wind-load figures with your enquiry, and we will match the panel, bracket and fixing schedule to them. As an exterior wall panels supplier we also coordinate the trims, joints and setting-out details, so what is fixed on site matches the approved drawing.

Leave a message
姓名
电子邮件*
信息