A close look at this panel shows a green onyx-style surface: a pale green ground crossed by cream-white and golden-brown veining, finished with a polish that gives the face a glossy, mineral depth. None of it is quarried. The stone look is produced on the board itself, so the pattern you approve is the pattern that runs across the elevation, without the block-to-block variation that comes with natural slabs.
Because the surface is made rather than cut, a project can ask for a specific stone and work to it. Send us the reference — a photograph of the stone, a finish already used on another elevation, or a physical sample — and we produce to a colour code rather than to a general "stone" description. Confirm that code against the approved sample before production, and keep each elevation to panels from the same production run so the field reads as one surface from the ground to the parapet.
The finish behaves differently according to where it is used. In direct sun the polish picks up the light and the veining reads more strongly; on a shaded or north-facing wall the same panel looks deeper and calmer. Indoors, under artificial light, the surface sits closest to the reference image. On a project where the look matters, check the panel in the light it will actually be seen in before the whole elevation is drawn into the order.
Direction matters on a large field. The veining is a designed pattern, not a repeating tile, so decide which way it should run and record that on the layout drawing before anything is cut. On a wide elevation, set the joint grid out first and let the pattern fall inside it rather than letting the pattern dictate where the joints land; the same drawing then carries the setting-out for the fixings.
This is the surface to choose when an elevation needs the weight and familiarity of stone. It sits comfortably beside exterior metal facade panels, timber and brick, and it reads as a stone finish both at the distance a passer-by sees it and at the distance a visitor stands from the entrance wall.
| Property | Value |
|---|---|
| Product code | CP-ST-027 |
| Panel type | Inorganic fibre decorative board |
| Surface | Polished stone-look pattern |
| Length | Up to 3,050 mm |
| Width | Up to 1,220 mm |
| Thickness | 4–15 mm; exterior walls typically 10 mm or 12 mm, interior walls 4, 6, 8 or 10 mm |
| Density | Approx. 950–1,200 kg/m³ depending on series |
| Moisture movement | 0.1% or less |
| Screw withdrawal | At least 1,870 N |
| Fire classification | Class A non-combustible (material classification) |
| Surface durability | Stain, scratch and wear resistant |
| Colour | Stone-look; pattern set by the selected code |
The fire question has three separate parts, and they are worth separating before anything goes into a submission: how the decorative surface reacts, how the board material itself behaves, and how the finished wall construction performs. The material classification belongs to the board on its own. The ninety-minute result our tested wall-panel system is documented at, at 1,200 °C, belongs to a specific assembly — panel, substrate, joints and fixings together. Change any one of those and the figure no longer describes your wall, which is why we ask for the build-up before pointing anyone at a report.
Smoke behaviour is reported separately again, as Class t0, with no toxic volatile organic compounds detected. On an escape route or in a public interior that line usually matters as much as the fire rating itself, and it is one of the reasons institutional projects specify inorganic boards rather than polymer finishes.
We can hand over third-party test reports covering fire resistance, mould resistance, VOC emissions and radioactivity, and direct you to the ones your submission needs. What makes that pack accurate is the information you send us: the wall build-up, the substrate, the joint widths, the fixing method and the market you are building to. Approvals are granted locally by the authority or consultant reviewing the project — our job is to make sure the documents describe the wall that is actually being installed.
One practical note: keep the fire documents on the same drawing revision as the fixing details. Assemblies change late in a programme more often than anyone expects, and a report that no longer matches the as-built build-up is worth very little at handover.
This panel belongs to the stone-texture band of the range — a run of codes covering stone looks from fine, even grain through to bold, high-movement patterns such as the onyx-style surface on this product. When a project wants a different stone character on a secondary elevation, or a quieter surface inside a lift lobby, the same band is where to look: the setting-out, thickness family and fixing methods stay the same while only the pattern changes.
The range does not stop at stone. The metal-look band produces the surfaces we supply for exterior metal wall panels, and the wood-look band gives a warm timber appearance without timber's moisture and maintenance behaviour. All three use the same inorganic sheet, and that matters more than it sounds: a mixed façade can be drawn once, on one thickness family, with one fixing logic and one set of handling rules, instead of three packages that have to be coordinated on site.
Choosing between them usually comes down to what an elevation has to say. Stone reads as mass and grounding — good for the base of a building, the main field, or a wall that should feel permanent. Metal reads crisp and technical and suits long horizontal runs, entrance reveals and industrial or transport buildings. Wood-look warms a surface and works well on soffits, canopies and interior walls where people come close enough to touch it.
A fourth line sits alongside these three. The aluminium mosaic range is a decorative interior product for feature walls, reception areas and washrooms, specified for its pattern. It is a different job from the boards on this product and should not be read as a façade or fire-rated panel.
The board itself is inorganic and fully glass-phase — no timber, no gypsum core, no resin binder — so it does not take up water and swell the way organic sheets do, and it offers mould nothing to feed on. Mould resistance forms part of the performance testing on this material, and that report can be released to your project.
Water absorption is a material figure rather than a wall figure, and it should be read against the thickness you are specifying. Ask your sales contact for the absorption value and the test method behind it for your panel gauge, and keep that document with the fixing and fire papers in the same submission. Where the panel faces weather as part of a ventilated exterior metal wall panels build-up, the cavity and its drainage do the weather work; the panel is the rain screen, and the waterproofing line stays behind it.
For wet interior areas — bathrooms, kitchens, balconies, washrooms, hospital and school sanitary zones — the panel is a finish, not the waterproof layer. Seal the joints and the cut edges with the sealant the detail calls for, fix to a substrate suited to a wet room, and keep the falls and drainage working behind the finish.
If mould ever appears on a wall finished this way, look at the build-up first: trapped moisture, a cold bridge, a blocked cavity or poor ventilation are the usual causes, and the panel is rarely the source. Keeping the cavity clear, the joints sealed and the substrate dry is what holds the surface clean over its service life.
CERSAIPANEL is the brand of Yulin Keli Keying Technology Co., Ltd., a building-material manufacturer established in 2016 and based in Yulin, Shaanxi, where we run our own production base with a workforce of 140. Manufacturing and export sit under one roof, so buyers in Europe, North and South America and Australia deal directly with the people who make the goods. Our full range is backed by third-party testing and the international certifications the company holds, and we take on OEM work and custom orders, from first sample through repeat production.
It is a manufactured panel — an inorganic fibre board made from coal gasification slag, melted and restructured in two stages at 1,500 °C, with the stone pattern produced on its face rather than cut from a block. Because the material is inorganic and vitreous, it is not a resin, polymer or carbon-fibre-reinforced composite, and it does not carry the variation of a quarry: the pattern you approve is the pattern that runs across the elevation. This stone-texture band and the metal-look surfaces sit on the same board, which is why we are among the exterior metal wall panels manufacturers producing both.
Yes. Send us the reference — a photograph, a sample of the stone it has to sit beside, or a finish already used on another elevation — and the pattern is produced on the board with high-definition 3D printing and electron-beam curing. The closer the match needs to be, the more useful a physical reference is, because screens and print shift greens and browns considerably. If the stone texture is going next to exterior metal facade panels or a timber finish on the same scheme, include that in the same conversation, so the tone relationship between the two is agreed before production rather than on site.
Yes — the board is made for both, and it is the same sheet we supply as metal exterior wall panels and wood-look boards. What changes is the detailing around it. Exterior walls need the fixing method, sealing, flashing and drainage set out in the project's system design, and the joints have to be arranged to shed water. Interior walls are simpler: the same panel goes onto the prepared substrate, with sealed joints where the wall is wet. Tell us where the panel is going and we will set the specification accordingly.
By setting it out on a drawing before the panels are cut. Decide the direction the veining runs, place the joint grid so the joints read as part of the design, and work out the order in which panels are set out so similar areas of pattern are not fixed next to each other. On a long field it helps to review the first section once it is up, before the rest of the elevation follows, and to keep each elevation to panels from a single production run so the tone does not step from one end to the other.
Yes, and it is a common way to use the range. The metal-look faces we supply as exterior metal wall panels, and the wood-look boards, are produced on the same inorganic sheet at the same thickness options, so a scheme can move from a stone field to a metal entrance reveal without changing substrate or fixing family. Agree the joint and the transition trim where the two finishes meet, and check both against the same setting-out drawing so the thicknesses line up on site.
Uplift and wind load decide the fixing on an exposed or high wall, and mechanical fixing — riveting, or dry hanging on a sub-frame — is normally used there rather than bonding alone. Send the wall height, the exposure, the substrate and the project engineer's wind-load figures with your enquiry, and we will match the panel, bracket and fixing schedule to them. As an exterior wall panels supplier we also coordinate the trims, joints and setting-out details, so what is fixed on site matches the approved drawing.